; GSD File for RP1000 PA
; Order-No.:
; File : RKS1183.gsd for AI + TOT
; Updata: for HaiNan J34
; Support Config: AI, AI+TOT
;*******************************************************************
;----- General DP Key Words
#Profibus_DP
GSD_Revision=5
Vendor_Name="ROCKSENSOR"
Model_Name="RP1000 Pressure AI"
Revision="1.8"
Ident_Number=0x1183
Protocol_Ident=0 ; 0 = PROFIBUS-DP
Station_Type=0 ; 0 = DP-Slave
FMS_supp=0
Hardware_Release="V1.0"
Software_Release="V1.2.1"
31.25_supp=1
45.45_supp=1
93.75_supp=1
MaxTsdr_31.25=100
MaxTsdr_45.45=250
MaxTsdr_93.75=1000
Redundancy=0
Repeater_Ctrl_Sig=0
24V_Pins=0
Implementation_Type="SPC42/tmg-itec"
Bitmap_Device="rks1000"
;----- Basic DP-Slave Related Key Words
Freeze_Mode_supp=0
Sync_Mode_supp=0
Set_Slave_Add_supp=1
Fail_Safe=1
Min_Slave_Intervall=200
Modular_Station=1
Max_Module=2
Max_Input_Len=10
Max_Output_Len=2
Max_Data_Len=12
Unit_Diag_Bit(16)="Status appears"
Unit_Diag_Bit(17)="Status disappears"
Unit_Diag_Bit(24)="Hardware failure electronics"
Unit_Diag_Bit(25)="Hardware failure mechanics"
Unit_Diag_Bit(26)="Motor temperature too high"
Unit_Diag_Bit(27)="Electronic temperature too high"
Unit_Diag_Bit(28)="Memory error"
Unit_Diag_Bit(29)="Measurement failure"
Unit_Diag_Bit(30)="Device not initialized"
Unit_Diag_Bit(31)="Device initialization failed"
Unit_Diag_Bit(32)="Zero point error"
Unit_Diag_Bit(33)="Power supply failed"
Unit_Diag_Bit(34)="Configuration invalid"
Unit_Diag_Bit(35)="Restart"
Unit_Diag_Bit(36)="Coldstart"
Unit_Diag_Bit(37)="Maintenance required"
Unit_Diag_Bit(38)="Characteristics invalid"
Unit_Diag_Bit(39)="Ident_Number violation"
Unit_Diag_Bit(55)="Extension available"
;Empty module
Module="No DATA " 0x00
0
EndModule
;AI.OUT
Module="AI Output " 0x94
1
EndModule
;TOT.TOTAL
Module="TOT Counter output " 0x41,0x84,0x85
2
EndModule
Max_Diag_Data_Len=20
Slave_Family=12@RKS
Max_User_Prm_Data_Len = 8
Ext_User_Prm_Data_Const(0) = 0x00,0x00,0x08,0x05,0x41,0x00,0x00,0x01
; DPV1 parameters
; SetPrm is structured
; Structure_Length = 5
; Structure_Type = 65 (profile specific)
; Slot_Number = 0
; reserved = 0
; PRM_COND=1 (enabled)
Prm_Block_Structure_supp = 1
Prm_Block_Structure_req = 0
PrmCmd_supp = 0
PrmCmd_req = 0
Slave_Max_Switch_Over_Time=20 ;=200 ms
Slave_Redundancy_supp=1
Ident_Maintenance_supp=1
;----- Slave related keywords for DP extensions
DPV1_Slave=1
C1_Read_Write_supp=1
C2_Read_Write_supp=1
C1_Max_Data_Len=72
C2_Max_Data_Len=72
C1_Response_Timeout=400
C2_Response_Timeout=400
C1_Read_Write_required=0
C2_Read_Write_required=0
C2_Max_Count_Channels=4
Max_Initiate_PDU_Length=52
Diagnostic_Alarm_supp=0
Process_Alarm_supp=0
Pull_Plug_Alarm_supp=0
Status_Alarm_supp=0
Update_Alarm_supp=0
Manufacturer_Specific_Alarm_supp=0
Extra_Alarm_SAP_supp=0
Alarm_Sequence_Mode_Count=0
Alarm_Type_Mode_supp=0
Diagnostic_Alarm_required=0
Process_Alarm_required=0
Pull_Plug_Alarm_required=0
Status_Alarm_required=0
Update_Alarm_required=0
Manufacturer_Specific_Alarm_required=0
DPV1_Data_Types=0
Check_Cfg_Mode=0
;----- Additional keywords for module assignment
SlotDefinition
Slot(1) = "Analog Input (AI)" 1 0,1
EndSlotDefinition