;********************************************************************* ;** ** ;** GSD File for Rosemount 3051 Pressure Transmitter ** ;** Date: 10/30/2018 ** ;** RMT14444.GSD ** ;********************************************************************* ; #Profibus_DP GSD_Revision = 5 Station_Type = 0 Protocol_Ident = 0 Vendor_Name = "Rosemount Inc." Model_Name = "3051 Pressure Transmitter" Revision = "2.0" Ident_Number = 0x4444 Hardware_Release = "5" Software_Release = "3.0.0" 9.6_supp = 1 19.2_supp = 1 31.25_supp = 1 45.45_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_31.25 = 100 MaxTsdr_45.45 = 250 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 Implementation_Type = "RMT ASIC/Hornet" Bitmap_Device = "3055555N" ;******************************************************************** ;** Slave specific Data ** ;******************************************************************** Freeze_Mode_supp = 0 Sync_Mode_supp = 0 Auto_Baud_supp = 0 Set_Slave_Add_supp = 1 Min_Slave_Intervall = 200 ;******************************************************************** ;** User Specific Parameterization -Data ** ;******************************************************************** ;User_Prm_Data_Len = 3 Max_User_Prm_Data_Len = 8 PrmText=1 Text(0)="Disabled" Text(1)="Enabled" EndPrmText ExtUserPrmData=1 "Condensed Status" Bit(0) 1 0-1 ;PRM_COND Prm_Text_Ref=1 ;reference to PrmText EndExtUserPrmData ;The Prm_Structure begins at an offset of three bytes in the User_Prm_Data ;because DPV1_Status1...3 are transmitted in the first three bytes Ext_User_Prm_Data_Const(0) = 0x00, 0x00, 0x08 Ext_User_Prm_Data_Const(3)=0x05,0x41,0x00,0x00,0x01 ;default values ;Structure_Length = 5 ;Structure_Type = 65 (profile specific) ;Slot_Number = 0 ;reserved = 0 ;PRM_COND = 1 (enabled) Ext_User_Prm_Data_Ref(7)=1; ;reference to condensed status bit PRM_COND Prm_Block_Structure_supp=1 ;enables the block structure of extended parameterization ;******************************************************************** ;** extended DP features ;******************************************************************** DPV1_Slave = 1 C2_Read_Write_supp = 1 C2_Max_Data_Len = 239 C2_Read_Write_required = 1 C2_Max_Count_Channels = 2 Max_Initiate_PDU_Length = 52 C2_Response_Timeout = 1000 DPV1_Data_Types = 1 Ident_Maintenance_supp = 1 ;----------- Description of device related diagnosis: ------------------------- ; ;Unit_Diag_Bit(16) = "Error Appears" ;Unit_Diag_Bit(17) = "Error Disappears" Unit_Diag_Bit(35) = "Warmstart" Unit_Diag_Bit(36) = "Coldstart" ;Unit_Diag_Bit(37) = "Maintenance" ;Unit_Diag_Bit(39) = "Ident_Number Violation" Unit_Diag_Bit(40) = "Maintenance Alarm" ;Unit_Diag_Bit(41) = "Maintenance Demanded" Unit_Diag_Bit(42) = "Function Check" ;Unit_Diag_Bit(43) = "Invalid Process Conditions" Unit_Diag_Bit(55) = "Extension Available" ;----------- Vendor specific diagnosis: ------------------------- Unit_Diag_Bit(60) = "Simulate Active" ;Unit_Diag_Bit(63) = "Other" Unit_Diag_Bit(64) = "Out of Service" Unit_Diag_Bit(65) = "Power-Up" ;Unit_Diag_Bit(66) = "Device Needs Maintenance Now" ;Unit_Diag_Bit(68) = "Lost NV Data" ;Unit_Diag_Bit(69) = "Lost Static Data" Unit_Diag_Bit(70) = "Memory Failure" ;Unit_Diag_Bit(73) = "ROM Integrity Error" Unit_Diag_Bit(75) = "NV Memory Integrity Error" Unit_Diag_Bit(76) = "Hardware-Software Incompatible" ;Unit_Diag_Bit(77) = "Man. Block Integrity Error" Unit_Diag_Bit(78) = "Sensor Transducer Block Error" Unit_Diag_Bit(79) = "LOI malfunction" ;******************************************************************** ;** Compact Station ** ;******************************************************************** Modular_Station = 1 Max_Module = 1 Max_Input_Len = 5 Max_Output_Len = 0 Max_Data_Len = 5 Max_Diag_Data_Len = 32 Slave_Family = 12 ;----------- Module definitions: ---------------------------------------------- ; ;Modules for Analog Input Module = "Analog Input (AI)short" 0x94 1 EndModule ;Modules for Analog Input Module = "Analog Input (AI)long" 0x42,0x84,0x08,0x05 2 EndModule ; ;----------- Description of the module assignment: ---------------------------- ; SlotDefinition Slot(1) = "Analog Input" 1 1,2 EndSlotDefinition